Enable Kyocera, TA and UTAX printers for tier counting
Basic MFP Setup:
- Ensure that the MFP is updated to the latest available firmware level.
- The MFP must be connected to a network port and link lights must be active.
- The MFP must have at least one empty application slot (under System Menu > Applications).
Enabling 3-tier color:
Please refer to the MFP’s Service Manual for instructions on enabling and setting up 3-tier color
coverage.The outline of the steps includes:
- Enter Maintenance Mode.
- Open U332: Adjust Coverage Size Calculation Rate.
- Rate: Set a value between 1.0 and 3.0. Default: 1.0.
- Mode: Set to 1.0 to enable 3-tier color coverage counts.
- Level 1 and Level 2: must be set between 0.1 and 99.9. Default: 1.0 and 2.5 respectively.
NOTE: The threshold values must be set for the Tiered Color Monitor to work correctly and effectively